WS-7026U
Wireless 433 MHz
Radio-Controlled Weather Station
Instruction Manual
ꢀ
INVENTORY OF CONTENTS
1. The Weather Station (Figure 1).
2. One TX4U Thermo Hygro Sensor with mounting bracket (Figure 2).
3. Three each ½” Philips screws.
4. One strip double-sided adhesive tape.
5. Instruction Manual and Warranty Card.
Figure 1
Figure 2
Forecast LCD
Indoor LCD
Outdoor LCD
ꢀ
ADDITIONAL EQUIPMENT (not included)
1. Four fresh AA 1.5V batteries.
2. One Philips screwdriver.
ABOUT WWVB (Radio Controlled Time)
The NIST (National Institute of Standards and Technology—Time Frequency
Division) WWVB radio station is located in Ft. Collins, Colorado and transmits the
exact time signal continuously throughout the United States at 60 kHz. The signal
can be received up to 2, 000 miles away through the internal antenna in the weather
station. However, due to the nature of the Earth’s Ionosphere, reception is very
limited during daylight hours. The weather station will search for a signal every
night when reception is best. The WWVB radio station derives its signal from the
NIST Atomic clock in Boulder, Colorado. A team of atomic physicists are
continually measuring every second, of every day, to an accuracy of ten billionths of
3
a second per day. These physicists have created an international standard measuring
a second as 9,192,631,770 vibrations of a Cesium-133 atom in a vacuum.
QUICK SET-UP GUIDE
1. Insert two AA batteries into the Thermo Hygro Sensor.
2. Insert two AA batteries into the WEATHER STATION.
3. Wait 5 minutes or until the outdoor temperature and humidity are
displayed in the OUTDOOR LCD (Liquid Crystal Display).
4. Wait 6-10 minutes (in ideal reception conditions) for the WWVB time
to be displayed in the TIME LCD. If the WWVB takes longer to set,
you may manually set the time (see complete instructions). Or you can
wait until after the weather station conducts its programmed search at
the ideal reception time period of 12:00 AM to 6:00 AM.
5. Mount the units ensuring that all units are sending and receiving
signals.
Note: The Thermo Hygro Sensor transmits a signal every 3 minutes. After
the batteries have been installed, the weather station will search for the
signal for a duration of 5 minutes. If there is no temperature reading in the
OUTDOOR LCD after 5 minutes, make sure the units are within range of
each other or repeat the battery installation procedure.
DETAILED SET-UP GUIDE
I. BATTERY INSTALLATION
A. THERMO HYGRO SENSOR
1. Pull the cylindrical rain cover off the sensor.
2. Remove the battery cover (located on the backside
of the sensor above the mounting post and bracket).
3. Press the arrow and slide the battery cover off.
4. Observing the correct polarity install 2 AA
batteries.
5. Replace battery cover and place rain cover
snugly onto the sensor.
B. WEATHER STATION
1. Remove the battery cover. To do this, insert
a solid object in the space provided at the
4
lower-central position of the battery cover, then push up and pull out
on the battery cover.
2. Observe the correct polarity and install 2 AA batteries.
3. Replace the battery cover.
Battery
Cover
Note: Immediately after the batteries have been installed, each LCD
(Liquid Crystal Display) will flash and a tone will sound. Within a few
seconds the indoor temperature, indoor relative humidity and the
weather icons (sun and clouds) will be displayed. If not, then remove
batteries for 10 seconds and reinstall. If the outdoor temperature is not
displayed within four minutes, remove batteries from both units, wait 10
seconds and reinstall. The time will show -:-- and start searching for
the signal. If it successfully receives the time signal (usually at night), it
will display the correct time (default is Eastern).
5
PROGRAM MODE
Programming Note: If 30 seconds is allowed to pass or either the IN or the
OUT button is pressed during programming modes, the unit will set the last
information entered—the display will stop flashing and return to normal
time-date readings. If you don’t leave the program mode during the
programming of sections III through VIII, you can advance to step 3 of the
next program setting. If you do leave the program setting (or want to
program a specific setting) follow each instructional step to program that
setting.
I. FUNCTION KEYS
The function keys are operated by pressing the top or bottom of the key
corresponding to the operation that you want to perform.
II. 12 OR 24 HOUR TIME SETTING
1. Press and hold the SET button for 3 seconds or until “12 h”
flashes in the DATE LCD.
2. Press the CH button to toggle between 12 and 24-hour time.
3. Press the SET button to confirm the 12/24-hour setting and to
advance to Time Zone Setting.
III. TIME ZONE SETTING
The default time zone is EST “-5hr” (Eastern Standard Time). To
change this setting:
1. Press and hold the SET button for 3 seconds or until “12 h”
OR “24 h” flashes in the DATE LCD.
2. Press the SET button 1 more time to enter the Time Zone
setting mode. The default Time Zone “-5” will flash in the
DATE LCD.
3. Select your appropriate time zone using the CH button.
During selection of the Time Zone, the 3 letter abbreviations
for the time zones found in North America will flash across
6
the TIME LCD. Observe the chart below showing the
corresponding abbreviations, time zones and codes.
TIME ZONES
GMT
Atlantic
Eastern
Central
Mountain
Pacific
0
-4
-5
-6
-7
-8
-9
-10
EST;
CST;
MST;
PST;
ALA;
HAW;
Alaska
Hawaii
Note: There are more time zones represented by numbers than there are
represented by 3 letter abbreviations. If you live in North America you
need only be concerned with the ones in the chart above.
4. Press the SET button to confirm and advance to the Daylight
Saving Time setting.
IV. DAYLIGHT SAVING TIME (DST) SETTING
1. Press and hold the SET button for 3 seconds or until “12 h” or
“24 h” flashes in the DATE LCD.
2. Press the SET button 2 more times to reach the DST selection
mode. “DST 1” is the default setting and will be flashing in
the DATE LCD.
3. Press the CH button to select “DST 0” or “DST 1.”
4. “DST 0” indicates that the feature is off and the WWVB will
not change times automatically. “DST 1” indicates that the
feature is on and the WWVB will change times automatically.
Note: Some locations (Arizona and parts of Indiana) do not
follow Daylight Saving Time, and should select “DST 0.”
5. Press the SET button to confirm and advance to the Time
setting mode.
7
V. TIME
There are two methods by which the time can be set:
A) Automatically via WWVB reception or
B) Manually
A. WWVB (Remote Control Time)
This method requires you to do nothing except wait for the signal
to be received and to select a time zone. Reception usually takes
approximately 6-10 minutes during optimal conditions. The best
conditions for reception is at night, between midnight and 6:00
AM, when there is less atmospheric interference. To keep your
time as accurate as possible, the weather station conducts a
WWVB search every night between these hours and overrides any
manually set time. The WWVB tower icon (appearing in the TIME
LCD) will flash when a signal-search is in progress, will remain
steady when the signal has been received, and nothing will be
displayed in all other situations. If the WWVB time has not been
received after 10 minutes of battery installation, you may manually
set the time or leave the time function alone (reception will occur
regardless).
B. MANUAL TIME SETTING
1. Press and hold the SET button for 3 seconds or until “12h”
flashes in the DATE LCD.
2. Press the SET button 3 more times (until the hour digit
flashes in the TIME LCD).
3. Press the CH button to change the hour.
4. Press the SET button to confirm the hour setting, and to
advance to the minute setting mode.
5. The minute digits will be flashing. Press the CH button to
change the minutes. Increasing the minutes by increments of 1
with each press of the CH button.
6. Press the SET button to confirm the minutes and to advance to
the Day, Date and Year setting mode.
8
Note: In 12h mode, “PM” will appear to the left of the time
during PM hours. If the time is not within the PM hours, nothing
will be displayed. Be sure to set the time to the correct AM/PM
time to ensure automatic reception at optimal times.
VI. SETTING THE DAY, DATE, AND YEAR
1. Press and hold the SET button for 3 seconds or until “12 h” or
“24 h” flashes in the DATE LCD.
2. Press the SET button 5 more times to reach the Weekday
setting mode.
Note: “MO” (representing Monday) is the default setting for the
weekday, “1.1” is the default setting for the numeric month and
day and “1999” is the default setting for the year. The day, date
and year will be automatically set once the WWVB signal is
received. However, the day, date and year can be manually set and
will flash respectively in the DATE LCD during manual
programming.
3. The weekday will be flashing in the DATE LCD. Press the
CH button to change the weekday.
4. Press the SET button to confirm and to enter the numeric-
month setting mode.
5. The numeric-month will be flashing in the DATE LCD. Use
the CH button to set to the current month.
6. Press the SET button to confirm the numeric-month and to
enter the numeric-day setting mode.
7. The numeric-day will be flashing. Use the CH button to set
the current day.
8. Press the SET button to confirm and to enter the year setting
mode.
9. The default-year will be flashing. Use the CH to set the
appropriate year.
10. Press the SET button to confirm and to advance to the °F or °C
setting mode.
9
VII. SELECTING °F OR °C
1. Press and hold the SET button for 3 seconds or until “12h” or
“24h” flashes in the DATE LCD.
2. Press the SET button 9 times to reach the °F or °C setting
mode.
3. “°F” is the default setting and should be flashing in the DATE
LCD.
4. Press the CH button to shift °F to °C and back.
5. Press the SET button to confirm your selection and to advance
to the LCD contrast setting.
VIII. SETTING THE LCD CONTRAST
1. Press and hold the SET button for 3 seconds or until “12h” or
“24h” flashes in the DATE LCD.
2. Press the SET button 10 more times to reach the LCD contrast
setting mode.
3. The default setting—“Lcd 5”—will flash in the DATE LCD.
4. There are 8 LCD contrast levels to choose from—“Lcd 0” is
the lightest and “Lcd 7” is the darkest.
5. Press the CH button to toggle through the settings.
6. Press either the IN or OUT buttons to confirm all the settings
and to exit the manual-programming mode (or wait 15
seconds for the unit to automatically return to the normal
display mode).
10
FEATURES OF THE WS-7026U
WWVB Tower Icon (indicates time
reception)
Alarm icon
Weather Tendency Arrow
Forecast icon
Comfort Level Indicator
Satellite icon (indicates
outdoor transmission)
I. BACKLIGHT
The WS-7026U has a backlight that can be activated by pressing any of the
eight function buttons. After a button has been pressed, the backlight will
come on for five seconds before automatically shutting off.
II. WEATHER FORECAST
The weather forecasting feature is estimated to be 75% accurate. The
weather forecast is based solely upon the change of air pressure over time.
The WS-7026U averages past air-pressure readings to provide an accurate
forecast—creating a necessity to disregard all weather forecasting for 12-24
hours after the unit has been set-up, reset or moved from one altitude to
another (i.e. from one floor of a building to another floor). In areas where
the weather is not affected by the change of air pressure, this feature will be
less accurate.
11
A. WEATHER ICONS
There are 3 possible weather icons that will be displayed in the
FORECAST LCD:
Sunny—indicates that the weather is expected to improve (not that
the weather will be sunny).
Sun with Clouds—indicates that the weather is expected to be fair
(not that the weather will be sunny with clouds).
Clouds with Rain—indicates that the weather is expected to get
worse (not that the weather will be rainy).
The weather icons change when the unit detects a change in air
pressure. The icons change in order from “sunny” to “partly
sunny” to “cloudy” or the reverse. It will not change from “sunny”
directly to “rainy”, although it is possible for the change to occur
quickly. If the symbols do not change, then the weather has not
changed or the change has been slow and gradual.
B. WEATHER TENDENCY ARROWS
Other possible displays in the FORECAST LCD are 2 weather
tendency arrows. One that points up (on the left side of the LCD)
and one that points down (on the right side of the LCD). These
arrows reflect current changes in the air pressure. An arrow
pointing up indicates that the air pressure is increasing and the
weather is expected to improve or remain good. An arrow
pointing down indicates that the air pressure is decreasing and the
weather is expected to become worse or remain poor. No arrow
means the pressure is stable.
III. INDOOR TEMPERATURE, HUMIDITY, AND COMFORT
LEVEL INDICATOR
12
The current Indoor Temperature (viewed on the left) and Relative Humidity
(viewed on the right) are displayed in the INDOOR LCD. The Comfort
Level Indicator is located at the center of the INDOOR LCD. The indicator
will display a happy face icon when the temperature is between 68°F and
79°F (20°C and 25.9°C) and the humidity is between 45% and 64%. A sad
face icon will be displayed when the temperature and humidity are outside
the mentioned ranges.
IV. OUTDOOR TEMPERATURE & HUMIDITY
The outdoor temperature and humidity is viewed in the OUTDOOR LCD.
When there is more than one Thermo Hygro Sensor unit in operation, a
“boxed” number will appear to the right of the temperature. This indicates
which Thermo Hygro Sensor unit (1, 2, or 3) is currently displaying its data
in the OUTDOOR LCD. (This feature is explained in further detail in
section VI—Adding Outdoor Thermo Hygro Sensors).
V. MINIMUM AND MAXIMUM TEMPERATURE RECORDS
The WS-7026U keeps a record of the MINIMUM and MAXIMUM
temperature, the time and date of their occurrence—for both the indoor and
outdoor modes.
A. VIEWING THE INDOOR TEMPERATURE RECORDS
1. Press the IN button once. “MIN” appears in the upper-center
location of the flashing INDOOR LCD, indicating that the
minimum temperature (along with the humidity measured at
that time) and the time and date of occurrence are displayed.
The minimum records will display for 20 seconds.
2. Press the IN button again (once while “MIN” is still displayed,
twice otherwise). “MAX” appears in the upper-center
location of the flashing INDOOR LCD, indicating that the
maximum temperature (along with the humidity measured at
that time) and the time and date of occurrence are displayed.
3. While “MAX” is still displayed, press the IN button again to
return to the current data display. Or you can wait 20
13
seconds, during either the minimum or the maximum readings,
and the unit will automatically return to current data readings.
B. VIEWING THE OUTDOOR TEMPERATURE
RECORDS
1. Press the OUT button once. “MIN” appears in the upper-
center location of the flashing OUTDOOR LCD, indicating
that the minimum temperature, the time and date of
occurrence are displayed. The minimum records will display
for 20 seconds.
2. Press the OUT button again (once while “MIN” is still
displayed, twice otherwise). “MAX” appears in the upper-
center location of the flashing OUTDOOR LCD, indicating
that the maximum temperature, the time and date of
occurrence are displayed.
3. While “MAX” is still displayed, press the OUT button again
to return to the current data display. Or you can wait 20
seconds, during either the minimum or the maximum readings,
and the unit will automatically return to current data readings.
C. RESETTING THE MIMIMUM AND MAXIMUM
RECORDS
1. All the Indoor records (minimum and maximum) will be reset
after the IN button is pressed and held for 5 seconds.
2. All the Outdoor records (minimum and maximum) will be
reset after the OUT button is pressed and held for 5 seconds.
VI. ALARM FUNCTION
A. SETTING THE ALARM (alarms 1 and 2)
Note: There are two alarms that can set. Each alarm will sound
for a complete duration of 2 minutes.
1. Press and hold the AL1 button for 5 seconds or until the
alarm-time display flashes in the DATE LCD.
14
2. Press the IN button to set the alarm hours and the OUT button
to set the alarm minutes.
3. Press the AL1 button or wait 15 seconds for the unit to
automatically confirm the alarm time and return to display the
date in the DATE LCD as normal.
4. The ((1)) icon, appearing in the DATE LCD, indicates that the
alarm is set to sound at the programmed time.
5. Programming the alarm time automatically activates the alarm
to sound at the programmed time. To deactivate the alarm,
press the AL1 button (removing the ((1)) icon from the
screen). To reactivate the alarm, press the AL1 button again.
6. After each activation or deactivation, the programmed alarm
time is displayed. Wait 15 seconds and the date will display
in the DATE LCD again.
7. To set, activate and deactivate alarm 2, follow the directions
above for alarm 1—using the AL2 button instead of the AL1
button.
The ((2)) icon will represent activation and
deactivation of alarm 2.
B. SNOOZING AND STOPPING THE ALARM
1. The snooze function is activated by pressing any one of the
following buttons: SET, IN, OUT or SNZ.
2. To turn the alarm off completely, press any of these buttons:
CH, AL1, AL2 or DATE.
3. The snooze function will last for 5 minutes before the alarm
begins to sound again. Either the ((1)) or the ((2)) icon will
flash during the snooze mode.
VII. ADDING OUTDOOR THERMO HYGRO SENSORS
(OPTIONAL)
The WS-7026U is able to receive signals from as many as 3 different
Thermo Hygro Sensors. The Remote Sensor model(s) that you choose will
come with their own set of instructions—follow these instructions for a
complete guide to setting up. Following are some brief instructions for the
basic set-up of Remote Sensor units with the WS-7026U. These extra
sensors can be purchased through the same dealer as this unit or by
15
contacting La Crosse Technology directly. A TX4U will monitor
temperature and humidity, a TX3U will monitor temperature only and the
TX3UP will monitor the temperature via a probe for use in pools, spas, etc.
Note: When setting up multiple units it is important to remove the batteries
from all existing units in operation, then to insert batteries first into all the
Remote Sensor units, and in numeric sequence. Second, install batteries
into the Indoor Temperature Station. Transmission problems will arise if
this is not done correctly and if the total time for set-up exceeds 6 minutes.
A. SET-UP OF MULTIPLE UNITS
1. It is necessary to remove the batteries from all units currently
in operation.
2. Remove the battery covers to all Remote Sensor units.
3. Place all Remote Sensor units in a numeric sequential order.
4. In sequential order, install batteries (follow the same battery
installation procedures seen in section I. A) of the Detailed
Set-Up Guide).
5. Install batteries into the Indoor Temperature Station.
6. Follow the Detailed Set-Up Guide for programming and
operating instructions.
B. VIEWING AND OPERATING WITH MULTIPLE
THERMO HYGRO SENSOR UNITS
1. To view the temperature of a different Thermo Hygro Sensor
unit, press the CH button. A shift from one “boxed” number
to the next should be observed in the OUTDOOR LCD.
2. To view the Minimum/Maximum temperature: first select
which Thermo Hygro Sensor to read data from (indicated by
the “boxed” number). Then press the OUT button. Pressing
this button once will display the minimum temperature, the
date and time the data was recorded. Pressing this button a
second time (while “MIN” is still displayed, otherwise press
the button twice) will display the same data for the maximum
recordings.
3. To reset the Minimum/Maximum readings, it is necessary to
select which Thermo Hygro Sensor you wish to reset. Press
16
and hold the OUT button for 5 seconds, the records for the
selected Thermo Hygro Sensor unit will be reset.
MOUNTING
Note: Before permanently mounting, ensure that the Indoor Temperature
Station is able to receive WWVB signals from the desired location. Also,
extreme and sudden changes in temperature will decrease the accuracy of
the weather station and changes in elevation will result with inaccurate
weather forecasting for the next 12 to 24 hours. These changes will require
a 12 to 24 hour wait before obtaining reliable data. To achieve a true
temperature reading, avoid mounting where direct sunlight can reach the
Thermo Hygro Sensor. We recommend that you mount the Thermo Hygro
Sensor on a North-facing wall. The sending range is 80ft—obstacles such
as walls, concrete and large metal objects can reduce the range. Place
both units in their desired location and wait approximately 10 minutes
before permanently mounting to ensure that there is proper reception. The
Indoor Weather Station should display a temperature in the OUTDOOR
LCD within 4 minutes of setting up.
I. THERMO HYGRO SENSOR
A. MOUNTING WITH THE SCREWS
1. Remove the mounting bracket/receptor from the packaging.
2. Place the mounting bracket over the desired mounting surface.
Through the 2 screw holes of the bracket, mark the mounting surface
with a pencil.
3. Where marked, start the screw holes using the provided screws.
Remove screws from the mounting surface.
4. Align the mounting bracket with the started screw holes.
17
5. Screw mounting bracket onto the mounting surface. The screws should
be flush with the bracket.
6. Fit the mounting post (on the back of the sensor) into the receptor of
the mounting bracket.
B. MOUNTING WITH ADHESIVE TAPE
1. With a nonabrasive solution, clean and dry the back of the mounting
bracket and the mounting surface to ensure a secure hold. The
mounting surface should be smooth and flat.
2. Remove the protective strip from one side of the tape. Press firmly
onto the designated area on the back of the mounting bracket.
3. Remove the protective strip from the other side of the tape and situate
the mounting bracket. Firmly press the mounting bracket onto the
mounting surface.
4. Fit the mounting post into the receptor of the mounting bracket.
II. THE INDOOR TEMPERATURE STATION
The Indoor Temperature Station can be mounted in two ways:
•
•
with the table stand or
on the wall with the use of a wall hanging screw (not included).
A. USING THE TABLE STAND
1) The Indoor Temperature Station comes with the table stand already
mounted. If you wish to use the table stand, all that is required is to place
the Indoor Temperature Station in an appropriate location.
B. WALL MOUNTING
1) Remove the table stand. To do this, pull down on the stand from the rear
and rotate forward.
2) Fix a screw (not included) into the desired wall, leaving approximately 3/16
of an inch (5mm) extended from the wall.
18
3) Place the Indoor Temperature Station onto the screw using the hanging hole
on the backside. Gently pull the Station down to lock the screw into place.
19
TROUBLESHOOTING
Problem: No reception of WWVB time signal.
Solution: 1) Wait overnight for signal.
2) Be sure weather station is at least 6 feet from any electrical devices such
as televisions, computers or other radio-controlled clocks.
3) Remove batteries for five minutes. Reinsert and leave the unit alone
overnight without pressing buttons.
4) If there are still problems, contact La Crosse Technology
Problem: Hour is incorrect (minute and date are correct)
Solution: Be sure correct time zone and daylight saving time are selected.
Problem: The LCD is faint
Solution: 1) Set the LCD contrast to a higher number
2) Replace batteries
Problem: No outdoor temperature is displayed.
Solution: 1) Remove all batteries, reinsert into sender first, then display.
2) Place remote sender closer to display.
3) Be sure all batteries are fresh.
NOTE: For problems not solved, please contact La Crosse Technology.
20
MAINTENANCE AND CARE INSTRUCTIONS
•
•
Extreme temperatures, vibration and shock should be avoided to prevent
damage to the units.
Clean displays and units with a soft, damp cloth. Do not use solvents or
scouring agents. They may mark the displays and casings.
Do not submerge in water.
•
•
Immediately remove all low powered batteries to avoid leakage and
damage.
•
Opening the casings invalidates the warranty. Do not try to repair the unit.
Contact La Crosse Technology for repairs.
21
SPECIFICATIONS
Temperature measuring range:
Indoor:
32°F to 139.8°F with 0.2°F
resolution. (0°C to 59.9°C with
0.1°C resolution). “OFL”
displayed if outside this range.
-21.8°F to 157.2°F with 0.2°F
resolution. (-29.9°C to 69.9°C
resolution). “OFL” displayed if
outside this range.
Outdoor:
Relative Humidity measuring
range:
19% to 95% with 1%
resolution. (“- -” displayed if
outside this range)
Indoor Temperature checking
interval:
Every 10 seconds
Indoor Humidity checking
interval:
Every 1 minute
Every 1 minute
Outdoor Temperature and
Humidity checking interval
(Thermo Hygro Sensor):
Outdoor Temperature and
humidity reception (Weather
Station):
Every 3 minutes
Transmission Range:
Power Supply:
80 feet (in open space)
Weather Station:
Sensor:
Battery life cycle:
Recommended battery type:
2 x AA, IEC LR6, 1.5V
2 x AA, IEC LR3, 1.5V
Approximately 12 months
Alkaline
Dimensions (L x W x H)
Weather Station (without
stand):
3.2 x 1.1 x 5.7 in
(81 x 30 x 145mm)
1.56 x 0.78 x 4.29 inches
(40 x 20 x 110 mm)
Thermo Hygro Sensor:
22
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against
manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on products
purchased and used in North America and only to the original purchaser of this
product. To receive warranty service, the purchaser must contact La Crosse
Technology, Ltd for problem determination and service procedures. Warranty service
can only be performed by a La Crosse Technology, Ltd authorized service center.
The original dated bill of sale must be presented upon request as proof of purchase to
La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our option and at no
charge as stipulated herein, with new or reconditioned parts or products if found to be
defective during the limited warranty period specified above. All replaced parts and
products become the property of La Crosse Technology, Ltd and must be returned to
La Crosse Technology, Ltd. Replacement parts and products assume the remaining
original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd
will pay all expenses for labor and materials for all repairs covered by this warranty. If
necessary repairs are not covered by this warranty, or if a product is examined which
is not in need or repair, you will be charged for the repairs or examination. The owner
must pay any shipping charges incurred in getting your La Crosse Technology, Ltd
product to a La Crosse Technology, Ltd authorized service center. La Crosse
Technology, Ltd will pay ground return shipping charges to the owner of the product to
a USA address only.
Your La Crosse Technology, Ltd warranty covers all defects in material and
workmanship with the following specified exceptions: (1) damage caused by accident,
unreasonable use or neglect (including the lack of reasonable and necessary
maintenance); (2) damage occurring during shipment (claims must be presented to
the carrier); (3) damage to, or deterioration of, any accessory or decorative surface;
(4) damage resulting from failure to follow instructions contained in your owner’s
manual; (5) damage resulting from the performance of repairs or alterations by
someone other than an authorized La Crosse Technology, Ltd authorized service
center; (6) units used for other than home use (7) applications and uses that this
product was not intended or (8) the products inability to receive a signal due to any
source of interference.. This warranty covers only actual defects within the product
itself, and does not cover the cost of installation or removal from a fixed installation,
normal set-up or adjustments, claims based on misrepresentation by the seller or
performance variations resulting from installation-related circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES
23
ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT.
THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR
PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF
CHILDREN’S REACH.
This warranty gives you specific legal rights. You may also have other rights specific
to your State. Some States do no allow the exclusion of consequential or incidental
damages therefore the above exclusion of limitation may not apply to you.
For warranty work, technical support, or information contact:
La Crosse Technology
2809 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
e-mail:
(warranty work)
(information on other products)
web:
FCC ID: OMO-01RX (Receiver), OMO-01TX (sensor)
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS:
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
2. THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
24
|