La Crosse Technology Thermostat WS 9029U User Manual

WS-9029U  
915 MHz  
WIRELESS WEATHER STATION  
INSTRUCTION MANUAL  
 
This product offers:  
INSTANT TRANSMISSION is the state-of-the-art new  
wireless transmission technology, exclusively  
designed and developed by LA CROSSE  
TECHNOLOGY. INSTANT TRANSMISSION offers you  
an immediate update (every 4 seconds!) of all your  
outdoor data measured from the sensors: follow  
your climatic variations in real-time!  
12 or 24 Hour  
Time Display  
Indoor Temperature  
(°F or °C)  
Indoor Humidity  
(%RH)  
Channel Indicator  
(1, 2, or 3)  
Connection  
w/ Sensor Icon  
Outdoor Temperature  
(°F or °C)  
Low Battery  
Indicator  
Minimum or Maximum  
Temperature & Humidity  
Set/  
Channel Button  
Minimum/Maximum/+  
Button  
FIGURE 1  
FEATURES  
Wireless Weather Station (Figure 1).  
Remote Temperature Sensor with optional Channel 2 Probe (TX25U, Figure 2).  
Indoor Temperature (°F or °C) and Indoor Humidity.  
Wireless Outdoor Temperature (°F or °C).  
Optional Channel 2 Temperature Probe.  
Able to Receive up to 3 Remote Temperature Sensors.  
3
 
Wall Hanging or Free Standing.  
Remote  
Temperature Sensor  
LCD Temperature Display  
Optional Probe  
w/ 10 Foot Wire  
Wall-Mounting  
Bracket  
FIGURE 2  
ADDITIONAL EQUIPMENT (not included)  
1. Two fresh AA 1.5V alkaline batteries for the wireless weather station.  
2. Two fresh AAA 1.5V alkaline batteries for the remote temperature sensor.  
3. One, Philips screwdriver for mounting.  
QUICK SETUP  
Hint: Use good quality Alkaline Batteries; avoid rechargeable batteries.  
1. Have the Wireless Weather Station and Temperature sensor 3 to 5 feet apart.  
2. Batteries should be out of both units for 10 minutes.  
3. Place the batteries into the Temperature sensor first and next into the Wireless Weather  
Station.  
4. DO NOT PRESS ANY BUTTONS FOR 15 MINUTES.  
In this time the Wireless Weather Station and the temperature sensor will begin to communicate with  
each other, and the display will show both the indoor temperature and an outdoor temperature. If the  
Wireless Weather Station does not display both temperatures after the 15 minutes, please retry the  
set up as stated above. After both indoor and outdoor temperatures are displayed for 15 minutes you  
can place your temperature sensor outdoors, and set your time.  
The temperature sensor should be placed in a dry, shaded area (ex: under the eve of a roof). The  
temperature sensor has a range of 330 feet. Any walls that the signal will have to pass through will  
reduce distance. An outdoor wall or window will have up to 20 feet of resistance and an interior wall  
will have up to 10 feet of resistance. Your distance plus resistance should not exceed 330 feet in a  
straight line.  
NOTE: Fog and mist will not harm your temperature sensor, but direct rain must be avoided.  
4
 
DETAILED SETUP GUIDE  
I. BATTERY INSTALLATION (When one Temperature sensor is being used)  
1. First, insert the batteries to the Temperature sensor (see “A. Temperature sensor” below).  
2. Within 2 minutes of powering up the sensor, insert the batteries to the Weather Station (see  
B. Wireless Weather station” below). Once the batteries are in place, all segments of the  
LCD will light up briefly. Following the indoor temperature and the time as 12:00 will be  
displayed, and the signal reception icon will flash. If they are not shown in LCD after 60  
seconds, remove the batteries and wait for at least 60 seconds before reinserting them. Once  
the indoor data is displayed user may proceed to the next step.  
3.  
After the batteries are inserted, the Weather Station will start receiving data signal from the  
sensor. The outdoor temperature should then be displayed on the Weather Station. If this does  
not happen after 2 minutes, the batteries will need to be removed from both units and reset  
from step 1.  
Battery  
Cover  
A. TEMPERATURE SENSOR  
1. Remove the Battery Cover.  
2. Observing the correct polarity, install 2 “AAA” Alkaline  
Batteries—make sure they do not spring free, or start-up  
problems may occur.  
3.Replace the Battery Cover.  
Battery  
Compartment  
Remote  
Temperature  
Sensor (TX-25U)  
B. WIRELESS WEATHER STATION  
Note: After the batteries are installed, DO NOT press any buttons. This may interfere with the  
signals, causing temperatures to register incorrectly.  
1. Remove the Battery Cover on the back of the Wireless Weather Station.  
2. Observing the correct polarity, install 2 “AA” Alkaline Batteries.  
3. Replace Battery Cover.  
4. Wait 15 minutes before pressing any buttons.  
Battery  
Compartment  
Battery  
Cover  
Wireless Weather  
Station  
Sensor signal  
reception icon*  
5
 
* When the signal is successfully received by the Weather Station, the icon will be switched on. (If not  
successful, the icon will not be shown in LCD) So the user can easily see whether the last reception  
was successful (icon on) or not (icon off). On the other hand, the short blinking of the icon shows that  
a reception is being done now.  
FUNCTION KEYS  
The simple design of this product features 2 keys.  
SET/CH:  
Press and hold for 5 seconds to enter set-up mode.  
Press and release to toggle between channels.  
MIN/MAX/+:  
Press and release to toggle between minimum, maximum, and current temperature values.  
Press and hold 5 seconds to reset all minimum and maximum recorded values.  
Press and release to advance hours and minutes.  
Press and release to toggle between 12 hour time and 24 hour time.  
OPERATIONS  
12 OR 24 HOUR TIME SETTING  
1. Press and hold the SET/CH button for 5 seconds.  
2. “12h” will flash in the Time section of the LCD.  
3. Press and release the MIN/MAX/+ button to toggle between 12 hour time and 24 hour time.  
4. Press and release the SET/CH button to confirm selection and advance to the time setting.  
Note: Selecting 12 hour time will automatically select Fahrenheit (°F) temperature. Selecting 24  
hour time will automatically select Celsius (°C) temperature.  
TIME SETTING  
1. Press and hold the SET button for 5 seconds.  
2. “12h” or “24h” will appear flashing in the TIME section of the LCD.  
3. Press and release the SET/CH button once.  
4. The hour will begin flashing.  
5. Press and release the MIN/MAX/+ button to advance the hours.  
6. Press and release the SET/CH button once more, and the minutes will begin to flash.  
7. Press and release the MIN/MAX/+ button to advance the minutes.  
8. Press and release the SET/CH button to confirm selection.  
Note: When in the 12-hour format “PM.” will appear to the left of the hour in the time LCD between  
the hours of noon and midnight.  
OUTDOOR TEMPERATURE  
The temperature received from the remote temperature sensor is viewed in the OUTDOOR LCD.  
When there is more than one remote temperature sensor unit in operation, a “boxed” number will  
appear to the right of the temperature. This indicates which remote temperature sensor unit (1, 2, or  
3) is currently displaying its data in the OUTDOOR LCD. (This feature is explained in further detail in  
the section—Adding Remote Temperature Sensors).  
VIEWING MINIMUM AND MAXIMUM TEMPERATURE RECORDS  
The WS-9029U keeps a record of the MINIMUM and MAXIMUM indoor and outdoor temperatures.  
6
 
To view minimum and maximum temperatures: press the min/max/+ button once. “MIN” appears in  
the bottom left of the LCD. The indoor and outdoor temperatures displayed when “MIN” appears are  
the minimum recorded values. The minimum records will display for 30 seconds before returning to  
the normal display mode.  
Press the min/max/+ button again (once while “MIN” is still displayed, twice otherwise). “MAX”  
appears in the bottom right of the LCD. The indoor and outdoor temperatures displayed when “MAX”  
appears are the maximum recorded values. The maximum records will display for 30 seconds before  
returning to the normal display mode.  
While “MAX” is still displayed press the min/max/+ button again to return to the current data display.  
Or you can wait 30 seconds, during either the minimum or the maximum readings, and the unit will  
automatically return to current data readings.  
RESETTING THE MIMIMUM AND MAXIMUM RECORDS  
All the minimum and maximum records (minimum and maximum) will be reset after the min/max/+  
button is pressed and held for 5 seconds.  
OPTIONAL CHANNEL 2 TEMPERATURE PROBE  
When the temperature probe is connected to the remote temperature sensor, the WS-9029U’s  
channel 1 will display the remote temperature sensor data, and channel 2 will display the temperature  
probe data. The remote temperature sensor data will always be displayed on the channel 1 and the  
temperature probe on the channel 2.  
If the probe on remote temperature sensor is unplugged, the "probe channel" on WS-9029U LCD will  
show "---", the remote temperature sensor displayed value will still be shown.  
The probe can be connected to the remote temperature sensor anytime. There is no need to reset the  
units. The Weather Station will automatically detect the temperature probe and will display the  
temperature probe data in channel 2.  
ADDING TEMPERATURE SENSORS (OPTIONAL)  
The WS-9029U is able to receive signals from 2 remote temperature sensors (TX-25U). These extra  
sensors can be purchased through the same dealer as this unit  
A. SET-UP OF MULTIPLE SENSORS  
1. Remove all the batteries from the receiver and sensor(s) and wait 60 seconds. During these  
60 seconds, press any button 20 times to discharge any excess power.  
2. Insert the batteries to the first sensor.  
3. Within 2 minutes of powering up the first sensor (Temperature sensor with probe), insert the  
batteries to the Weather Station. Once the batteries are in place, all segments of the LCD will  
light up briefly. Following the indoor temperature/humidity and the time as 12:00 will be  
displayed, and the signal reception icon will flash. If they are not shown in LCD after 60  
seconds, remove the batteries and wait for at least 60 seconds before reinserting them.  
4. The outdoor temperature from the first sensor (channel 1) should then be displayed on the  
Weather station. If this does not happen after 2 minutes, the batteries will need to be removed  
from both units and reset from step 1.  
5. If the temperature probe has been used, the outdoor temperature from channel 2 will then be  
displayed. Otherwise, the outdoor temperature will display “---“.  
Note: The temperature probe from the first sensor will always occupy “channel 2”. Channel 2 can  
only be used for the temperature probe. If you choose not to use the temperature probe, Channel  
2 will display “---“.  
6. Insert the batteries to the second sensor as soon as the outdoor temperature readings from  
the first sensor are displayed on the Weather station.  
7
 
NOTE: You must insert the batteries into the second sensor within 30 seconds of  
reception of the first sensor.  
7. The outdoor temperature from the second sensor and the "channel 3" icon should then be  
displayed on the Weather station. If this does not happen after 2 minute, the batteries will need  
to be removed from all the units and reset from step 1.  
Note: only the readings from the internal sensor of the second sensor will be displayed in “channel 3”  
IMPORTANT: Transmission problems will arise if the setting for additional sensors is not  
followed as described above. Should transmission problems occur, it is necessary to  
remove the batteries from all units and start again the set-up from step 1.  
B. VIEWING AND OPERATING WITH MULTIPLE TEMPERATURE SENSOR UNITS  
1. To view the temperature of a different remote temperature sensor unit, press and release the  
SET/CH button. A shift from one “boxed” number to the next should be observed in the  
OUTDOOR LCD.  
2. To determine which remote temperature sensor reading is displayed on the 3 channels, match the  
temperature displayed on each channel, with the corresponding temperature displayed on the  
LCD of each remote temperature sensor.  
3. To view the Minimum/Maximum temperature: first select which remote temperature sensor to read  
data from (indicated by the “boxed” number), then press the SET/CH button. Pressing this button  
once will display the minimum temperature, and the date and time the data was recorded.  
Pressing this button a second time (while “MIN” is still displayed, otherwise press the button twice)  
will display the same data for the maximum recordings.  
4. To reset the Minimum/Maximum readings, press and hold the MIN/MAX/+ button for 5 seconds,  
this will reset all the minimum and maximum data from all sensors.  
MOUNTING  
THE REMOTE TEMPERATURE SENSOR  
1. Remove the mounting bracket/stand from the temperature sensor.  
2. Place the mounting bracket over the desired location.  
3. The mounting bracket can attach to the sensor in the middle of the back or on the bottom.  
4. Through the 3 screw holes of the bracket, mark the mounting surface with a pencil.  
5. Screw mounting bracket onto the mounting surface. Ensure that the screws are flush with the  
bracket.  
6. Insert the remote temperature sensor into the bracket.  
Back middle of  
sensor inserted into  
Mounting Bracket  
Bottom of sensor  
inserted into Mounting  
Bracket  
8
 
THE WIRELESS WEATHER STATION  
The wireless weather station can be mounted in 2 ways:  
with the table stand or,  
on the wall with the use of a wall hanging screw (not included).  
A. USING THE TABLE STAND  
The wireless weather station comes with the table stand attached. If  
you wish to use the table-stand all that is required is to pull out the table  
stand on the back of the receiver and place the receiver on a flat  
surface.  
B. WALL MOUNTING  
1. Make sure the table stand is flush against the wireless weather  
station.  
2. Fix a screw (not included) into the desired wall, leaving  
approximately 1/4 of an inch (5mm) extended from the wall.  
3. Place the wireless weather station onto the screw using the hanging  
hole on the backside.  
4. Gently pull the wireless weather station down to lock the screw into  
place.  
TROUBLESHOOTING  
NOTE: For problems not solved, please contact La Crosse Technology.  
Problem: Hour is incorrect (minute and date are correct)  
Solution: Be sure correct time zone and daylight saving time settings are selected.  
Problem: The LCD is faint  
Solution: 1) Set the LCD contrast to a higher number  
2) Replace batteries  
Problem: No outdoor temperature is displayed.  
Solution: 1) Remove all batteries, reinsert into sensor first, then into the wireless weather station.  
2) Place remote temperature sensor closer to wireless weather station.  
3) Be sure all batteries are fresh.  
4) Place remoter temperature sensor and wireless weather station in position so the straight-line  
signal is not passing through more than 2 or 3 walls.  
Problem: Temperatures do not match if units are placed next to each other.  
Solution: Each remote temperature sensor is manufactured to be accurate to within 1 degree plus or  
minus and under normal conditions, so two sensors could be as much as 2 degrees different.  
However, the difference can be exaggerated further because the sensors are designed for  
different working environments. The indoor sensor is less responsive to ambient air currents  
because of the shielding effect of the display's case. In addition, the case can act as a heat  
sink to absorb and store heat from external sources (i.e. handling of the case or radiant heat).  
Also, the much greater range of the remote temperature sensor requires a different calibration  
curve than the indoor range. Error is usually greater at the extreme ends of a range, making it  
harder to compare different ranges with different curves. Under non-laboratory conditions, it is  
difficult to compensate for the above factors and obtain an accurate comparison.  
9
 
MAINTENANCE AND CARE INSTRUCTIONS  
9 Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units.  
9 Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they  
may mark the displays and casings.  
9 Do not submerge in water.  
9 Immediately remove all low powered batteries to avoid leakage and damage.  
9 Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse  
Technology for repairs.  
SPECIFICATIONS  
Temperature measuring range:  
14.1°F to 139.8°F with 0.1°F resolution.  
“OFL” displayed if outside this range.  
Indoor:  
-39.8°F to 139.8°F with 0.1°F resolution.  
“OFL” displayed if outside this range.  
Outdoor:  
1% to 99% with 1% resolution.  
(“- -” displayed if outside this range.  
Indoor relative humidity measuring range:  
Every 15 seconds.  
Indoor Temperature checking interval:  
Outdoor Temperature checking interval  
(Remote Control Sender):  
Every 4 seconds.  
330 feet (in open space).  
Transmission Range:  
Power Supply:  
2 x AA, IEC LR6, 1.5V.  
2 x AAA, IEC LR3, 1.5V.  
Approximately 24 months.  
Alkaline.  
Weather Station:  
Temperature Sensor:  
Battery life cycle:  
Recommended battery type:  
Dimensions (L x W x H)  
Weather Station  
2.91” x 1.15” x 3.86” (74 x 29.1 x 98mm).  
1.44” x 0.76” x 4.80” (36.6 x 19.3 x 121.8 mm)  
Temperature Sensor:  
WARRANTY INFORMATION  
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and  
workmanship.  
This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to  
the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem  
determination and service procedures. Warranty service can only be performed by a La Crosse Technology, Ltd authorized service  
center. The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse  
Technology, Ltd’s authorized service center.  
La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or  
reconditioned parts or products if found to be defective during the limited warranty period specified above. All replaced parts and  
products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts  
and products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd will pay all  
expenses for labor and materials for all repairs covered by this warranty. If necessary repairs are not covered by this warranty, or if a  
product is examined which is not in need or repair, you will be charged for the repairs or examination. The owner must pay any shipping  
charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service center. La  
Crosse Technology, Ltd will pay ground return shipping charges to the owner of the product to a USA address only.  
Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following specified exceptions: (1)  
damage caused by accident, unreasonable use or neglect (including the lack of reasonable and necessary maintenance); (2) damage  
occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorative  
10  
 
surface; (4) damage resulting from failure to follow instructions contained in your owner’s manual; (5) damage resulting from the  
performance of repairs or alterations by someone other than an authorized La Crosse Technology, Ltd authorized service center; (6)  
units used for other than home use (7) applications and uses that this product was not intended or (8) the products inability to receive a  
signal due to any source of interference.. This warranty covers only actual defects within the product itself, and does not cover the cost  
of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or  
performance variations resulting from installation-related circumstances.  
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER  
SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO  
BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF  
CHILDREN’S REACH.  
This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do no allow the  
exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you.  
For warranty work, technical support, or information contact:  
La Crosse Technology, Ltd  
2809 Losey Blvd. S.  
La Crosse, WI 54601  
Phone: 608.782.1610  
Fax: 608.796.1020  
e-mail:  
(warranty work)  
(information on other products)  
web:  
Questions? Please see:  
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic,  
mechanical or chemical procedures without written permission of the publisher.  
This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the  
next issue. We accept no liability for technical mistakes or printing errors, or their consequences.  
All trademarks and patents are acknowledged.  
11  
 

LevelOne Computer Hardware 11g USB Adapter w LCD WiFi Detector User Manual
Lexmark Printer 16M1260 User Manual
Lexmark Welder 5056 xxx User Manual
Life Fitness Exercise Bike 95R 0XXX 01 User Manual
Mackie Recording Equipment XD 2 User Manual
Magic Chef Juicer MCJ1W User Manual
Marshall electronic Microphone Large Capsule Vocal Condenser Microphone User Manual
Masterbuilt Electric Steamer 20010306 User Manual
Memorex DVD Player Digital Video Disc Player User Manual
Metra Electronics Automobile Accessories 95 7313 User Manual