Lynx Plus Series Control
WARRANTY INFORMATION
Quick Installation Guide
For the latest warranty information, please go to:
This Quick Installation Guide can help you install the rechargeable Lynx Plus Series Control quickly and easily by providing the
basic steps for installation using the built-in defaults and the Voice Prompt Programming mode. The Voice Prompt
Programming mode allows you to quickly program the system by responding to a series of voice prompts.
(see Lynx Plus Series Installation and Setup Guide P/N 800-03857 or higher)
1. Install the Control
2. Make Wiring Connections
3. Make Battery Connections
4. Program the Control
SCREW
Change the Installer Code
NOTE
WALYNXRCHKIT-SHA
BATTERY PACK SHOWN
WARNING
UL NOTE
The factory default Installer Code for the Lynx Plus Series Control is set
to 4-1-1-2. To change this code, you must enter Expert Programming
mode.
TO PREVENT
RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAGE
RETAINER
MOUNTING
HOOKS
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
AT TELECOM
NOTE
USE ONLY THE
K10145WH/K10145X10
OR K10145CN
TRANSFORMER
PROVIDED
JACK BEFORE
SERVICING
THIS UNIT
HARD
WIRED
ZONE
BATTERY PACK
1. After Power-up, enter Installer Code + 8 0 0 or press both the [7]
and [#] simultaneously within 50 seconds after power is applied to
the control. The system will enter the Expert Programming Mode
and “20 INSTALLER CODE” will be displayed.
6-14VDC 6-14VDC
30mA max. 120mA max.
INCOMING
TELEPHONE
LINE
2k
OHMS
EOLR
BACK
CASE
EARTH
GROUND
PREMISES
TELEPHONE
PIEZO
BELL
AC
AC
Note: Upon power-up or after exiting program mode, the system takes up
to a minute to reset. To bypass the reset delay, enter [#]+[0].
RING
TIP
RING
TIP
2. Enter 720
3. Enter a new four-digit Installer Code.
TELEPHONE
CONNECTION
K10145WH/K10145X10
OR K10145CN
PLUG-IN
TRANSFORMER
9VAC, 25VA
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
SOUND
OUT
8
R
3
R
5
HWZ
AC
11
T
2
T
4
AC
10
POS
JACK
1
INCOMING
PHONE
6
8
7
9
PLCD
CONNECTOR
Program variable data fields
1. If required, enter 724 to program the desired 2-digit RF House ID
for wireless keypads.
2. If required, enter 740 to program a PABX Access Code or to
LINE
BATTERY
CONNECTIONS
EARTH
GROUND
AC
PHONE
ZONE
SOUNDERS
GSML/GSMVL
COMMUNICATIONS
PORT
1000-100-004-V0
Disable Call Waiting (LynxSIA Plus only).
3. Enter 794 to program the downloading computer phone number.
GSMVL AUDIO
CABLE CONNECTOR
4. Press the ESCAPE/ OFF key to enter Voice Prompt Program
Note: For the complete Summary of Connections, refer to the Lynx Plus
FRONT
CASE
Series Installation and Setup Guide P/N 800-03857 or higher
mode. The system will announce, “Programming, use arrowsto scroll
choices, press select to accept, press escape to quit.” The system
will announce the available options.
1000-300-007-V0
LOCKING TABS
1000-300-011-V0
5. Follow the directions provided by each voice prompt to make your
selections.
1. Separate the front case from the rear case by rotating the front
case and releasing the hooks from the rear case.
2. Feed the wiring through the openings provided in the rear case.
3. Mount the rear case to a sturdy wall and secure with the provided
screws.
3. Reconnect the front case and rear case.
1. Make earth ground connections to terminal 1.
2. Connect the incoming phone line to either the 8-position jack or
terminals 2 (TIP) and 3 (RING).
3. Connect the handset phone lines to terminals 4 (TIP) and 5
(RING).
Note: For full line seize operation, refer to the Lynx Plus Series
Installation and Setup Guide.
4. If used, connect a piezo sounder or bell to terminals 8 (-) and 9
(+).
5. Connect the sensors/contacts to the hardwired zone terminals 6
(-) and 7 (+).
6. If used, connect the GSML or GSMVL communications device to
the GSML/GSMVL communications port.
1. Remove screw securing the battery retainer.
2. Remove the battery retainer.
3. Insert battery pack into back plate.
4. Install battery retainer.
5. Install screw to secure the battery retainer.
6. Connect battery connector to receptacle on PC board.
7. After all wiring connections have been made, snap the front
assembly to the back plate so it is held by the locking tabs.
8. Plug the transformer into a 24-hour, 110VAC unswitched
outlet.
Note: Rechargeable batteries may take up to 48-hours to fully
charge. “LOW BAT” message should clear within four hours,
or by entering Test Mode.
The FUNCTION/ # key can be used to repeat a voice prompt,
as required.
6. When you have completed each programming procedure the
system will return to the Main Programming Menu.
Viewing data fields
1. To view data entered in field, press [#] plus the field that you wish to view
(e.g., #21). The system will beep three times and data programmed for that
field will be displayed to the right of the field number. The system will scroll
through the data for longer numbers and a beep will sound after each
number is displayed or three times after the final digit is displayed.
7. Connect wires from the K10145WH/K10145 OR K10145CN
Transformer to terminals 10 and 11.
Note: If using Powerline Carrier Devices refer to the Lynx Plus Series
Installation Guide P/N 800-03857 or higher.
(Continued on reverse side)
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2009 Honeywell International Inc.
Ê800-03860/Š
800-03860 9/09 Rev. A
|